Crew Evaluation Test online for seamans about Wall Washing Cargo Tanks and Wall Wash Tests

Join Our Telegram (Seaman Community)

“Seagull CES marine test online about Wall Washing” (Crew Evaluation Test) will help marine specialists in preparation to exams for getting certificate of confidence.

This test contains 63 questions, you should answer on 60. Mode “Practice” and “Exam” have one difference – in “Exam” mode you can’t ask the computer to show you the right answer.

Choose mode in which you want take “CES” test:

Practice - CES test
Practice
Exam - CES test
Exam
Start test
A “failed” wall wash can result from:
Poor technique.
Dirty equipment.
Using a clean plastic spray bottle.
Traces of previous cargo.
Next question
Which of the following should be available in the ships laboratory?
An emergency eyewash bottle.
Material Safety Data Sheets for any chemicals in regular use.
Safety glasses.
A fresh water supply.
Show result
If you do not pay enough attention to the exact requirements of the Customer’s wall wash specification, which of the following may result?
Over-cleaning.
Unnecessary over use of cleaning chemicals.
Wasted time and manpower.
Tendering of a tank that does not meet the required standard.
Next question
The basic routine laboratory tests, that we run on board include:
Appearance.
Ultraviolet Spectrum.
Hydrocarbons.
Gas Chromatography.
Next question
Wall wash results should be recorded for the following reasons:
It is in all Captains Standing Orders.
It often figures as an item in Vetting Inspections.
It enables progress to be tracked during tank cleaning.
It is an ASTM requirement.
Next question
The two kinds of detectable odour in a wall wash sample are:
Residual.
Nominal.
Distinctive.
Characteristic.
Next question
A drying-oven Non-Volatile Matter test cannot be effectively done on board a ship, because:
The equipment works on a different voltage.
Spares are difficult to obtain in many parts of the world.
A sufficiently stable and vibration-free platform cannot be provided for the required measurements.
Ships laboratories cannot be maintained at constant room temperature.
Next question
A wall wash should not be taken from a hot bulkhead, because:
Any contaminants will stick to the surface.
Any contaminants will evaporate.
Too much Methanol will evaporate.
The Officer (or Surveyor) will burn his hands.
Next question
A wall wash should not be taken from a wet bulkhead, because:
Any contaminants will stick to the surface.
Any contaminants will collect at the bottom of the bulkhead.
The Methanol will evaporate on contact with the moisture on the bulkhead.
Surface tension and dilution will lead to a less efficient wall wash.
Next question
All cargoes loaded into Stainless Steel tanks require a wall wash standard of tank cleanliness:
True.
False.
Next question
An Inhibitor in a last cargo will almost certainly influence the result in this routine shipboard laboratory test:
Appearance.
Odour.
Hydrocarbons.
Permanganate Fade Time.
Next question
Another name for the Hydrocarbon test is “Water Misidentification”:
True.
False.
Next question
Blue graduation marks on the side of a test tube may lead to:
Misinterpretation of low levels of Hydrocarbons.
Increased levels of Hydrocarbons.
Poor analysis of Permanganate Fade Time.
Misinterpretation of high levels of Chlorides.
Next question
Certain ships routinely carry a stock of wall wash equipment in excess of the recommended levels, if:
They are below budget.
They regularly trade in the Far East.
They work in an intensive high-spec trade.
They carry a lot of acid cargoes.
Next question
Given the specification and observed condition as listed, what would be the priority in the next phase of tank preparation?
Hydrocarbons.
Chlorides.
Appearance.
Next question
Heavy smokers may, in particular, have a problem accurately conducting this routine laboratory test:
Colour.
Chlorides.
Odour.
Appearance.
Next question
Hot bulkheads should be avoided for wall wash, because:
Of safety concerns.
Of the high evaporation rate of the Methanol.
ASTM specifications require the bulkhead to be between 15 °C and 25 °C.
Accurate analysis is dependent on temperature at the time of wall wash in the tank.
Next question
How many drops of Silver Nitrate solution are added to the sample in a Chloride test?
5.
10.
2.
1.
Next question
Ideally, a standard wall-wash should be run over which of the following distances?
Minimum of half a metre.
At least one metre.
75 cm in open areas, 25 cm under frames.
Maximum of one metre.
Next question
If Bleach products have been used in a tank cleaning process, and not properly rinsed away, the following is most likely to be noted in a wall wash analysis:
Hydrocarbons.
Colour.
Suspended Matter.
Chlorides.
Next question
If you encountered a new wall wash or analysis procedure, you should:
Forward full details to Company Operations Department.
Advise the Ships Superintendand.
Ignore it.
Inform the Purchasing Department.
Next question
In a Hydrocarbons test, the presence of moderate to heavy Hydrocarbons is indicated by:
A milky white discoloration.
A silver sheen on the surface of the sample.
A translucent bluish tint.
A pale yellow haze.
Next question
In a Hydrocarbons test, the presence of slight Hydrocarbons is indicated by:
A milky white discoloration.
A silver sheen on the surface of the sample.
A translucent bluish tint.
A pale yellow haze.
Next question
In a Permanganate Fade Time test using Methanol, at what temperature should the samples be maintained?
25 °C.
15 °C.
10 °C.
Not more than 10 °C.
Next question
In a Permanganate Fade Time test, how long should the samples be allowed to “stabilize” before the Permanganate solution is added?
At least 10 minutes.
Maximum 30 minutes.
2 minutes.
Approximately 45 minutes.
Next question
In a Permanganate Fade Time test, samples should be checked against the standard at the following interval:
Every 10 minutes.
Every 30 minutes.
After 30 minutes and every 10 minutes thereafter.
Continuously.
Next question
Inhibitor in a previous cargo commonly affects Permanganate Fade Time test results:
True.
False.
Next question
Maintaining the samples at a constant temperature is a necessary part of the Permanganate Fade Time test procedure:
True.
False.
Next question
Most shore laboratories follow analysis standards laid down by:
IMO.
ISO.
ASTM.
Customer’s Cargo Handling Manuals.
Next question
Of the four problems listed below and assuming all are included in a customer specification, which would be the priority?
Appearance (some suspended matter).
Moderate Hydrocarbons.
Heavy Chlorides.
Very slight Odour.
Next question
Orange or red particles noted in a wall wash sample are an indication of the presence of:
Hydrocarbons.
Rust particles.
Undissolved Potassium Permanganate.
Chlorides.
Next question
Permanganate Fade Time is defined as:
The time elapsed from taking the wall wash until the colour of the sample matches the colour of the ASTM Colour-Standard.
The time elapsed from the “Start” time in the laboratory test until the colour of the sample matches the colour of the ASTM Colour-Standard.
The time for a prepared Permanganate Solution to go off-colour.
The time measured between placing the samples in the cooler until they reach 15 °C.
Next question
Permanganate Fade Time test samples should start off with the following colour:
A bluish tint.
A rich, deep purple.
Completely clear.
A pale, watery yellow.
Next question
Permanganate Fade Time test are run for:
40 minutes.
1 hour.
As long as a customer’s specification requires.
As long as the Chief Officer chooses.
Next question
Regular marker pens should not be used to identify sample jars, because:
You may need to remark them at a later stage.
Methanol may dissolve the marker ink.
Methanol will turn the marker ink sticky and it may get transferred to the wall wash funnel.
Under the regulations, coloured marker pens are prohibited.
Next question
Residual Odour is defined as:
The smell normally associated with a wall wash medium.
The smell associated with a clean and dry tank coating.
Any odour present in a cargo tank immediately prior to loading.
A foreign smell, typically from a previous cargo, found in a wall wash sample, but not present in a “blank”.
Next question
Soapy bubbles noted on the top of a wall wash sample in a test tube are a likely indication of:
Residues from an oil based cleaning agent.
Residues of a water based cargo.
Residues from a detergent based cleaning chemical.
Acetone.
Next question
Standard wall wash technique usually involves running a sufficient quantity of industrial water down a tank surface, until all traces of cargo residue disappear from a collected sample:
True.
False.
Next question
The Ultraviolet Spectrum test is run to detect:
Acid.
Hydrocarbons.
High levels of solid particle impurities.
Low levels of dissolved impurities.
Next question
The dish used in a shore laboratory Non-Volatile Matter test is commonly made from:
Potassium.
Stainless steel.
Platinum.
Teflon coated metal.
Next question
The following amount of Potassium Permanganate Solution is added to the sample in the Permanganate Fade Time test:
5 ml.
1 ml.
10 ml.
2 ml.
Next question
The following important information should be prominently posted in the ships laboratory:
The Deck Watch keeping Schedule.
A calendar.
Material Safety Data Sheets for any chemical in use.
Cleaning Chemical Index.
Next question
The letters “G. C.” in the shore laboratory test stand for:
General Condition.
General Chromatography.
Gas Condition.
Gas Chromatography.
Next question
The letters “N. V. M.” stand for:
Non-violet matter.
Normal volatile matter.
Non-violet matter.
Non-volatile matter.
Next question
The most apparent effect of samples left standing in test tubes is:
Permanent etching of the glass.
Accelerated discoloration of the glass.
Chemical reaction with any Hydrocarbons present.
Very slight inaccuracies in certain laboratory tests.
Next question
The most likely source of Hydrocarbons detected in a wall wash sample is:
Dust in the laboratory Methanol.
Polluted air drawn into the tank.
Traces of previous cargo.
Equipment failure.
Next question
The over-riding principle behind a wall wash and the subsequent analysis is:
Speed.
Agreement.
Cleanliness.
Selecting a good part of the tank, in order to ensure a “pass” result.
Next question
The purpose of a wall wash is to determine:
Whether a tank meets customer cleanliness requirements.
If a tank is dry.
Whether a tank meets company maintenance requirements.
If a tank is safe to enter.
Next question
The ratio and components used in the preparation of a Permanganate Solution are:
0,2 g Permanganate crystals to 0,5 ltr Deionised Water.
0,5 g Permanganate crystals to 0,5 ltr Deionised Water.
0,1 g Permanganate crystals to 0,5 ltr Methanol.
0,1 g Permanganate crystals to 0,5 ltr Deionised Water.
Next question
The risk of odour contamination is most likely in which of the following:
On the access ladder.
Tank lid and cleaning hatch packing’s.
Drop lines.
P/V Valves.
Next question
The sealed reference standard used in a Permanganate Fade Time test is:
A Potassium Chloride 600 colour standard.
A Potassium Chloride 530 colour standard.
An API 500 Colour standard.
A Platinum Cobalt 500 colour standard.
Next question
The significant difference with a Whatman Filter Paper test is that it:
Commonly includes a sample taken from the tank bottom.
Involves more samples per tank.
It is more difficult to pass.
It is only performed in Japan.
Next question
The two components in a Hydrocarbon test “blank” standard are:
Wall wash sample and Deionised Water.
Wall wash sample and Methanol.
Methanol and Silver Nitrate Solution.
Methanol and Deionised Water.
Next question
The wall wash procedures in this programme and those used by the majority of shore laboratories, are built around industry standards issued by the following organisation:
The American Society for Testing and Materials.
The American Petroleum Institute.
System International.
Det Norske Veritas.
Next question
To assess the Appearance of a wall wash sample, we:
Send the sample ashore for laboratory analysis.
Examine the sample in good light and compare to a sample of “good” Methanol.
Add Silver Nitrate and look for cloudiness.
Heat a small sample of the wall wash and check for any residues remaining.
Next question
To determine the presence of Chlorides in a wall wash sample, we add:
2 ml of 20 % Potassium Permanganate Solution.
5 drops of 10 % Silver Nitrate Solution.
2 mg of Potassium Permanganate crystals.
5 ml of 3 % Hydrochloric Acid.
Next question
Under normal handling conditions, a Permanganate Solution will last for approximately:
1 year.
1 month.
Indefinitely.
3-5 days.
Next question
Wall wash samples will not really be affected by an occasional drop of sweat:
True.
False.
Next question
When performing a Hydrocarbons test, the sample should be viewed:
Looking down through the tube against a black background.
Looking sideways through the tube against a good light.
Looking sideways through the tube against a black background.
Looking down through the tube against a white background.
Next question
Where possible, a wall wash stream should be run for:
Maximum 1 metre.
Minimum 1 metre.
2 metres.
At least 0,5 metre.
Next question
Which of the following descriptions is best applied to the “Appearance” of a wall wash sample?
The cloudiness of the sample.
The overall clarity and content of the sample.
The colour of any sediment in the bottom of the sample.
The number of floating particles (only) in a measured amount of the sample.
Next question
Which of the following is a false statement?
Methanol dissolves most kinds of marker ink.
A random area on each bulkhead is selected during wall wash to guarantee, so far as is practicable, a representative coverage.
Moisture on a bulkhead may lead to the build-up of surface tension, which is resistant to Methanol.
Brown “burn marks” around a Methanol stream are specifically indicative of salt crystals remaining on the bulkhead.
Next question
Which of the following is unlikely to be the source of Hydrocarbons found in wall wash analysis?
Previous cargo.
Equipment failure.
Inhibitor.
Staining from Inert Gas.
Next question