.
Our site needs your help!
Site categories
1/ Help
:

Crew Evaluation System CBT test online for seamans about Separators, ALCAP Separation Principles

Join Our Telegram (Seaman Community)

Welcome to the website where you can pass online the Computer Based Test (CBT) also known as Crew Evaluation System (CES) on the subject «Separators, ALCAP Separation Principles». Practice like this will help you as a marine specialist improve your knowledge with the help of online studying and appraisal practice. CES/CBT based on practical information and marine specialists experience.

CES & CBT tests developed for evaluating seaman basic knowledge by Seagull Company (rebranded as «OTG»), is an evaluating online-tool, used for revealing any professional preparation needed in specific fields of knowledge, defined by STCW.

CES tests have proven themselves as good tools for the selection and recruitment process, as well as advancing the level of knowledge of the current officers and crew. Ocean Technologies Group use various subjects for question creation, which includes:

  • Crowd and Crisis Management;
  • Integrated Navigation System (INS);
  • Ballast water management;
  • Handling and Stowage;
  • Vessel operation management and safety;
  • Marine engineering;
  • Maintenance and repair, etc.

Current test contains Seagull CES questions on the subject «Separators, ALCAP Separation Principles». Those questions can be used for competence verification specialist capable of preventing accidental situations related with transporting safety, or also for self-examination.

«Separators, ALCAP Separation Principles» subject includes theoretical and practical information about separation principles of an ALCAP separators. Knowledge of this information directly shows employee’s competence who holds a relevant post on a vessel, provides to understand operational rules and specifics of an ALCAP separators on a vessels, control liquid separation process, detect any malfunctions, be able to perform an emergency stop so that prevent system clogging or separator failure.

On this site Crew Evaluation System Test on the subject «Separators, ALCAP Separation Principles» contains 21 questions you need to answer with no possibility to go back to previous question. Therefore, we recommend carefully reading each question and making decision with no hurry. In case you have some difficulty answering, you have also possibility to request a hint.

Choose mode in which you want take CES test:

Practice - CES test
Practice
Exam - CES test
Exam
Start test
Based on what you have learned so far, which of the following statements are correct?
Free water and solids can be removed from oil in a clarifier.
Sealing and displacement water is not added to a purifier bowl.
Too low a separating temperature will not cause the interface to move into the disc stack.
An increase in viscosity will reduce separation efficiency.
Next question
Centrifugal separation has advantage over gravitational separation, because:
Separators are easier to install than large settling tanks.
Tank heating systems are complex.
Centrifugal force is many times greater than gravitational force.
Next question
During a partial discharge, the bowl opens for:
A few milliseconds only.
A few minutes only.
A few seconds only.
Next question
How are the solids removed from a Solid Bowl separator?
Through the drain holes.
By hand.
Through the solids discharge ports.
Next question
How long is the bowl open during a partial discharge?
A few minutes.
A few seconds.
A few milliseconds.
Next question
Identify from where the V/V Block is drawing Oil?
Storage Tanks.
Service Tank.
Settling Tank.
Next question
If the backpressure in the oil discharge line is increased, which of the statements is correct?
Oil level in paring chamber moves outwards.
Water level in paring chamber moves inwards.
Nothing happens.
Oil level in paring chamber moves inwards.
Next question
If the density of the oil being supplied to the purifier has increased, would you have to change the gravity disc?
Yes, always.
No, never.
Not necessarily, but a check should be made.
Next question
Increasing viscosity of a liquid makes it:
More pumpable and easier to flow.
Less pumpable and more difficult to flow.
Viscosity has no relationship with flow or pumpability.
Next question
So, can we increase the speed of separation?
Yes.
No.
Next question
The purpose of a purifier is to separate:
Liquids and solids.
Liquids of different densities.
Solids of different densities.
Next question
The purpose of the paring disc is:
To pump away the purified oil and water away from the bowl.
To pump purified oil and water into the bowl.
To enclose the bowl from the top end.
Next question
The recirculation valve is positioned close to purifier:
To lessen effect of temperature fluctuation when valve operates.
For ease of installation.
For ease of maintenance.
Next question
The time required for particles to separate in sedimentation depends on:
Speed and size.
Form and shape.
Colour and temperature.
Next question
To achieve the best possible results, the interface should be positioned:
As close as possible and within the top disc.
As far out as possible, but no further than the top disc.
Wherever it can be positioned.
Next question
What is a Solid Bowl separator suitable for?
Processing liquids with large solids volume.
Processing liquids with small solids volume.
Processing liquids with negligible solids volume.
Next question
What is the purpose of the oil paring disc?
To pour-off the water from the oil.
To keep the interface in the correct position.
To discharge the water under pressure.
To discharge the oil under pressure.
Next question
Which of the following cause the interface to move outwards?
Increase of Feed Temperature.
Decrease in Oil Density.
Decrease in Feed Flow.
Increase in Oil Density.
Next question
Why is a heater with PI (proportional and integral) required?
To keep steady control of temperature.
To avoid manual temperature control.
To allow for temperature fluctuation.
Next question
With decreasing back pressure, the inner level of liquid in the paring chamber:
Moves inwards.
Moves outwards.
Stays static.
Next question
Your Clarifier is NOT cleaning the liquid as it should. Click the alternative you think would improve cleaning:
Reduce the feed.
Increase the feed.
Reduce temperature of process liquid.
Increase temperature of process liquid.
Show result
* In some questions may be more, than one right answer.
“CES test” finished! Your result:

Did you find mistake? Highlight and press CTRL+Enter

Июль, 26, 2022 1824 0
SOC.MEDIA Telegram Vkontakte Facebook Odnoklassniki Instagram
Добавить комментарий