Our site needs your help!
Site categories
1/ Help
:

Crew Evaluation CBT Test Online on Exi Verification and Documentation (CD-8539)

Join Our Telegram (Seaman Community)

Welcome to the website where you can pass online the CES CBT CD-8539 test on the subject «Exi Verification and Documentation». Practice like this will help you as a marine specialist improve your knowledge with the help of online studying and appraisal practice. CES based on practical information and marine specialists experience.

CES tests developed for evaluating seaman basic knowledge by Seagull Company (rebranded as «OTG»), is an evaluating online-tool, used for revealing any professional preparation needed in specific fields of knowledge, defined by STCW.

CES tests have proven themselves as good tools for the selection and recruitment process, as well as advancing the level of knowledge of the current officers and crew. Ocean Technologies Group use various subjects for question creation, which includes:

  • Crowd and Crisis Management;
  • Integrated Navigation System (INS);
  • Ballast water management;
  • Handling and Stowage;
  • Vessel operation management and safety;
  • Marine engineering;
  • Maintenance and repair, etc.

Current test contains Seagull CES questions on the subject «Exi Verification and Documentation». Those questions can be used for competence verification specialist capable of preventing accidental situations related with transporting safety, or also for self-examination.

«Exi Verification and Documentation» subject includes theoretical and practical information about advanced training for work on any type of vessel. The test is designed to provide training for personnel working on ships of various types. The course provides comprehensive training for maritime professionals seeking to enhance their qualifications for working on different types of vessels. This advanced training program covers essential documentation procedures and verification protocols required for safe vessel operation. Sailors learn about international maritime regulations and standards that govern various types of ships and their documentation requirements. The course includes knowledge and exercises to ensure proper understanding of verification processes aboard different vessels. Participants study the specific documentation requirements for cargo ships, passenger vessels, tankers and other specialized marine transport. The training program emphasizes the importance of proper record-keeping and verification procedures in maintaining maritime safety standards. Participants gain expertise in handling emergency documentation and verification procedures across different types of marine vessels. The test prepares maritime professionals to effectively manage and verify essential documentation regardless of the vessel type they work on.

On this site Crew Evaluation System Test on the subject «Exi Verification and Documentation» contains 32 questions you need to answer with no possibility to go back to previous question. Therefore, we recommend carefully reading each question and making decision with no hurry. In case you have some difficulty answering, you have also possibility to request a hint.

Choose the regime, in which you want to pass CES test:

Training - CES test
Training
Exam - CES test
Exam
Wild Mode
* Some questions may have more than 1 correct answer.
“CES test” finished! Your result:
Correct answers:

Use the search below to find question.

Amount of questions: 32.

Right answers marked with this sign .

Can barriers be connected together in parallel or series?
Yes, refer to documentation or standard.
No, but one barrier may have several field devices.
No, one barrier allowed per field device.
Can low energy generating components be used as «simple apparatus». E. g. a photocell?
No.
Yes, with limitation.
Yes, without limitations.
Does simple apparatus need a T-class?
No.
Only for Zone 0 and Zone 1.
Yes.
Does simple apparatus need a certificate label?
No.
Only when applied in Zone 0 and Zone 1.
Yes.
For assessing equipment, which of the values shall be greatest?
Ui greater or equal than Uo.
Un greater or equal than Ui.
Uo greater or equal than Ui.
For assessing equipment, which of the values shall be greatest?
In greater or equal than Ii.
Ii greater or equal than Io.
Io greater or equal than Ii.
For assessing equipment, which of the values shall be greatest?
Nominal inductance greater or equal than Ii.
Li greater or equal than Lo.
Lo greater or equal than Li.
For assessing equipment, which of the values shall be greatest?
Ci greater or equal than Li.
Co greater or equal than Ci.
Nominal capacitance greater or equal than Ci.
How long cable can be installed where the Cc (allowed cable inductance) is 0,080 µF and the cable has a capacitance of 0,2 µF/km?
2 400 meters.
400 meters.
40 meters.
How much capacitance may the cable add where the circuit has the following instruments: Co – 0,11 µF, Ci – 87 nF?
0,023 µF.
76 µF.
98 nF.
How will the zener barrier affect the circuit?
All zener barriers connects the return signal to earth.
It’s connected directly in the circuit and adds resistance to the loop.
It provides a segregation for the loop.
If a field device has Gas group IIC stated on the equipment label, is this automatically suitable for an IIC environment?
Yes, as long as the component is marked for IIC, the equipment is suitable for IIC.
Yes, IS circuits and components will always achieve gas group IIC.
No, the documentation shall reflect the achieved gas group.
Is Ex nL equipment suitable for a «ib» circuit?
No, Ex nL may not be used in an intrinsically safe circuit.
No, only for an «ic» circuit.
Yes.
Is it a requirement to state the achieved T-class for components in an IS circuit?
Yes.
No.
Only for Certified Apparatus.
May a field device have several T-classes?
No, not for certified apparatus.
Yes, but only for simple apparatus.
Yes, refer to documentation.
May a simple apparatus be used in another circuit without any further verification?
No.
Only for IIA, «ic» circuits.
Yes.
May we use an IIC approved field device in an IIA circuit?
Yes.
Depends on the level of protection.
No.
Of the following, which can be used as simple apparatus in an IS circuit?
A transmitter.
Thermocouple.
Motor.
What T-class can be achieved for many simple apparatus based on the ambient temperature and Po from the associated apparatus?
T4.
T5.
T6.
What T-class can normally be allocated junction boxes and plugs when used as simple apparatus below 40 °C?
T1.
T4.
T6.
What T-class is achieved on junction boxes, terminals and plugs in an ambient temp below 40 °C?
T4.
T5.
T6.
What determines the T-class?
The field device documentation/label.
Only the ambient temperature.
Only the power from the associated apparatus.
What determines the gas group of the circuit?
The gas group stated on the field device.
The values used for the barrier during assessment of the circuit and the field device.
The values used for the barrier alone.
What happens to the circuit when we use a galvanic isolated barrier?
The control side is segregated from the IS side.
The control side is in direct electrical contact with the IS area.
The zero volt reference from the barrier is earthed.
What happens to the safety parameters if the inductance and the capacitance is above 1 % of the barrier?
The allowable values for Co and Lo are reduced with 50 %.
The allowable inductance are reduced with 50 %.
The allowable values for all parameters are reduced with 50 %.
What happens with the protection level when we connect two barriers in series or parallel and assess the system?
Nothing, as long as both are «ia».
Reduced from «ia» to «ic».
Reduced from «ia» to «ib».
What is a «DSD» for an intrinsically safe system?
The «Descriptive System Documentation».
The «Design System Dossier» (Translated from French).
The «Documentation, System Datasheets».
What level of protection is achieved if the associated apparatus is «ia» and the field device is «ib»?
This is not allowed.
«ia».
«ib».
«ic».
What level of protection is achieved if the associated apparatus is «ib» and the field device is «ia»?
This is not allowed.
«ia».
«ib».
«ic».
What will the achieved gas group be for an IIC component in an IIA circuit?
IIA.
IIB.
IIC, the field device is not affected by the circuit.
When can we use the L/R ratio instead of assessing the inductance of the cable?
Only when Li is less than 1 % of the Lo.
Only when Li is more than 1 % of the Lo.
Only when the capacitance is less than 1 % of Co.
Which standard describes the requirements for IS installations?
IEC 60079-11.
IEC 60079-15 and IEC 60079-11.
IEC 60079-14 and IEC 60079-25.